Pre-launch preview. Values marked Indicative are being verified against test certificates.
Aluminium · Lift & slide

Big glass that still closes like a vault.

Lift & slide doors carry very large panels on rollers, then lower them onto compressed gaskets when closed. You get a wide, slim-framed opening that stays airtight and quiet. We draw it with you, make it to order and fit it with our own team.

The data on this page is for aluminium. Lift & slide is also available in timber and PVC for smaller openings. Compare materials.

  • Panel weightup to 400 kg
  • Panel heightup to 3,200 mm
  • Panel widthup to 3,300 mm
  • Interlock sightlinefrom c. 50 mm
  • Thresholdflush or ≤15 mm
  • Whole-door Uwfrom c. 0.9 W/m²K

Indicative System-class envelope. Certified values are published with each system data sheet.

Elevation of a London rear extension with a four-panel centre-opening lift and slide door between brick piers, under a steel beam, with a flush threshold to the garden. steel beam — deflection to system limit fixedfixed linear drain structural opening 5,600 mm · 4 panels · centre opening 2,700 mm
Fig. 1 — Typical rear-extension opening, elevationOriginal drawing · not to scale
Choosing a system

Lift & slide, inline slider or bi-fold?

All three can work in a London extension. They differ in panel size, how much frame you see, how well they seal and how they feel to use every day. This is the comparison we talk clients through at Stage 2.

General comparison. Exact limits depend on the system and the glass.
Lift & slideInline slidingBi-fold
Largest panelVery largeUp to c. 400 kg and 3.2 m tallLargeUsually lighter hardware classesSmallPanels typically ≤1.2 m wide
Frame you see when closedOne slim interlock per meetingVery slim on minimal systemsA vertical frame every metre or so
Airtightness & weatherExcellentPanel drops onto compressed gasketsGoodMostly brush sealsGoodMany joints to seal
Clear opening50–67% of the widthNear 100% with a pocket50–67%Up to c. 90%
Everyday useTurn the handle, then the panel glidesPush to slideUnfold every panel
Best forWide garden elevations, big glass, exposed sitesContemporary minimal frames, moderate sizesOpening the whole wall in summer
How it works

A half-turn of the handle does the heavy lifting.

  1. Closed and lowered

    The panel sits down on its gaskets. Its own weight compresses them, which is why lift & slide doors seal so well against wind, rain and noise.

  2. Turn the handle 180°

    A gear in the sash lifts the panel a few millimetres onto steel rollers. The gaskets come clear of the frame.

  3. Slide and park

    The panel glides on the rollers with a light push. You can leave it at any position, and a soft-close damper is an option.

Schematic section through the bottom of a lift and slide panel: lowered onto gaskets on the left, lifted onto rollers on the right. Lowered — sealed gaskets compressed Lifted — free to slide lift panel on rollers, gaskets clear
Fig. 2 — Lift mechanism, schematicOriginal drawing
Configurations

Six layouts cover almost every opening.

Plan views. Accent lines are sliding panels; grey lines are fixed. We pick the layout from your opening width, the panel weight and where you want the door to park.

LS-2

Two panels, one sliding

The simplest layout and the best value. One panel parks behind the fixed one, so the clear opening is about half the width.

LS-3T

Three panels, three tracks

Two panels stack behind one fixed panel and open two-thirds of the width. Good when one side must stay clear.

LS-4C

Four panels, centre opening

The classic garden elevation: symmetrical, and the two middle panels part to the sides. It keeps panel weights down on wide openings.

LS-6C

Six panels, centre opening

For openings over about 7 m. Four panels slide on three tracks and two-thirds of the width opens.

LS-CNR

Corner, no post

Two sliding panels meet at a corner with no post, so the garden corner opens completely. The structure must carry the corner load instead: we coordinate this with your engineer at Stage 3.

LS-PKT

Pocket

The panels slide into a pocket in the wall, leaving the full width open and no frame in view. This needs a cavity designed for it, so it must be decided by Stage 3.

Sizing tool

Check panel size and weight before you draw it.

Enter the structural opening. The tool estimates panel width, glass weight, clear opening and handling needs, and flags the Approved Document L 25% rule for extensions. These are planning figures. We confirm the final numbers on project drawings.

Choose laminated for security, acoustic or barrier needs.

Assumptions: frame 70 mm, interlock overlap 70 mm, sash profile 140 mm, glass 2.5 kg/m² per mm, sash and hardware +15%.

Panel width
—
Approx. panel weight
—
Approx. clear opening
—
Opening area
—
    Save to your portalSend this to us for a checkWe reply with comments within 2 working days.
    Performance

    Design envelope

    The ranges a lift & slide system of this class achieves. On every project we issue the certified values for the exact system, size and glass, so you can quote them in your specification and your Part L calculation.

    Indicative We'll replace each range with the certified value and its test reference once the system data sheet is published.

    Aluminium lift & slide — thermally broken
    Thermal transmittance, whole door (Uw)c. 0.9–1.4 W/m²KTriple vs double glazing and size. Approved Document L limiting values: 1.4 for replacement doors in existing homes; 1.6 in new dwellings.
    Maximum panel weight300 kg standard / 400 kg heavy-dutySet by the roller and gear hardware class.
    Maximum panel sizec. 3,300 × 3,200 mmLarger on engineering review.
    Interlock sightlinefrom c. 50 mmSlim interlock option.
    Frame depthc. 160–220 mm2 or 3 tracks.
    ThresholdFlush (recessed) or low upstand ≤15 mmA ≤15 mm upstand meets the accessible-threshold expectation in Approved Document M.
    SecuritySpecified to PAS 24:2022Needed for doors in new dwellings under Approved Document Q.
    Weather (BS 6375-1 / EN 12207, 12208, 12210)Classified per system test reportWe match the classes to your site's exposure.
    Acoustic (Rw)up to c. 40 dBWith asymmetric laminated acoustic glass.
    Safety glazingToughened or laminated throughoutDoors and side panels are critical locations under Approved Document K.
    Schematic section through a flush threshold: the frame is recessed into the slab with insulation and screed inside and a linear drain outside. InsideOutside screed / finished floor insulation slab — recess formed to suit frame drain paving, falls away
    Fig. 3 — Flush threshold, schematic sectionOriginal drawing · not a construction detail
    Thresholds

    A flush threshold is a floor detail, not a door option.

    Getting inside and outside onto one level is the reason most clients choose lift & slide. It only works if the slab, insulation and drainage are drawn for it.

    • The slab needs a recess of the depth the system needs. We give you that dimension at Stage 3.
    • The thermal line has to run under the frame to avoid a cold bridge, so coordinate it with the insulation and any underfloor heating.
    • Outside, fit a linear drain and lay the paving to fall away. On exposed sites, a low upstand may be the safer choice.
    • For Part M, keep any upstand to 15 mm or less.
    Glass, finish, hardware

    Specified once, built exactly as drawn.

    Every component on your specification is the one we install. If a change is ever needed, we tell you in writing and show its effect on performance and certification before anything is ordered.

    Glass

    Double or triple

    Low-E, warm-edge spacers, argon fill. Options: solar control for south and west elevations (relevant to Part O), acoustic laminated glass near main roads and under flight paths, and laminated security glass.

    Finish

    Any RAL, dual colour

    Polyester powder coat to a recognised architectural standard, textured or matt finishes, and anodised options. Different colours inside and out are available at no structural penalty.

    Hardware

    Lift gear and rollers

    Branded lift-and-slide hardware sized to the panel weight. Choose slim, flush or lockable handles, multi-point locking and soft-close dampers.

    Extras

    Motorised and screened

    Concealed motorisation for very large panels, integrated insect screens and child-safety locks.

    Designing in London

    Four things that decide whether a big slider works.

    Most problems with large sliding doors start long before installation. These are the four we check on every set of drawings. The design guide covers each one in detail.

    01 · Structure

    Beam deflection

    A sliding head tolerates only a few millimetres of movement. Your engineer should design the beam to the system limit, not just to a general span ratio.

    02 · Floor

    Recess and drainage

    A flush threshold needs a formed recess, a continuous thermal line and a drain outside. All three must be fixed before the slab is poured.

    03 · Access

    Getting the glass in

    A 300 kg panel won't go through a Victorian hallway. We plan the route from kerb to opening at survey, and that can mean a crane licence.

    04 · Regulations

    Part L, O, K, Q

    Glazing over 25% of the extension floor area needs SAP. New homes need an overheating check, safety glass and PAS 24 security.

    Working with us

    What you get at each RIBA stage.

    We work as part of the design team rather than as a supplier who shows up at tender. Each stage ends with something you can use.

    1. Stage 2 · Concept

      Configuration and panel-size advice, a budget range and a check on structure and access.

      → budget ±15%
    2. Stage 3 · Spatial

      System recommendation, typical head, sill, jamb and threshold details, and the deflection limit for your engineer.

      → DWG details
    3. Stage 4 · Technical

      Project shop drawings, certified U-values for your sizes, loads on the structure and a fixed quotation.

      → drawings to sign off
    4. Stage 5 · Site

      Site survey, manufacture to signed drawings, delivery plan and installation by our own team.

      → installed & tested
    5. Stage 6 · Handover

      O&M manual, declarations of performance, the guarantee, and a check-in visit after the first season.

      → handover pack
    Technical files

    Lift & slide spec pack

    One download with everything you need to specify the door. We'll publish it when the system data sheet is certified. Until then, request it and we'll send the current drafts for your project.

    FileFormatStatus
    Head, sill, jamb & interlock detailsDWG · PDFPreparing
    Flush & low threshold detailsDWG · PDFPreparing
    BIM objectRVT · IFCPreparing
    NBS-style specification clauseDOCXPreparing
    Data sheet & declaration of performancePDFPreparing
    Installation & maintenance guidePDFPreparing
    Questions

    Lift & slide FAQ

    How wide can a lift & slide door be?

    There's no practical limit on overall width; it's a question of how many panels you use. Each panel is limited by weight (typically up to 400 kg) and size (around 3.3 m wide). Wide openings use four or six panels. Use the sizing tool for a first check.

    Is a 300 kg panel hard to open?

    No. Once lifted onto its rollers the panel needs only a light, steady push. The handle's gear does the lifting. For very large panels we offer concealed motorisation.

    Lift & slide or bi-fold for a London extension?

    Bi-folds open nearly the whole width, but you see a frame every metre or so when they're closed, and that's most of the year. Lift & slide gives bigger glass, slimmer sightlines and better sealing, with half to two-thirds of the width opening. See the comparison.

    Can I have a completely flush threshold?

    Yes, if the floor is designed for it: a recess in the slab, a continuous thermal line and drainage outside. On exposed or high sites, a low upstand of 15 mm or less is often the more robust choice and still meets Part M.

    Will it meet Building Regulations?

    For an extension, the door's U-value needs to meet the limiting value in Approved Document L, and the total glazing should stay within 25% of the extension floor area for the simple route. Above that, your energy assessor uses SAP. New dwellings also need PAS 24 security (Part Q), safety glazing (Part K) and an overheating assessment (Part O). We provide the data for each.

    Do I need planning permission?

    Many rear extensions fall under permitted development, but not in conservation areas where Article 4 directions apply, and not for listed buildings. Planning is your architect's call. We can supply elevations and sightline drawings for the application.

    Who makes and installs the doors?

    We make them to order on a branded system and install them with our own team. We don't subcontract fitting. You get one project manager from survey to handover.

    You're a new company. Why should we trust you with a big opening?

    That's a fair question. The answer is in what you can check: certified system data, a full-size sample before you order, written change control, our own installers and a guarantee from a UK company. Read how our founding projects work.

    Send us the opening. We'll send back a layout, a weight check and a budget.

    Size your opening Request a quote